Newer
Older
ONLINE_SSID=$(uci get wireless.client_radio0.ssid -q)
: ${ONLINE_SSID:=FREIFUNK} # if for whatever reason ONLINE_SSID is NULL
OFFLINE_PREFIX='FF_OFFLINE_' # use something short to leave space for the nodename (no '~' allowed!)
UPPER_LIMIT='55' # above this limit the online SSID will be used
LOWER_LIMIT='45' # below this limit the offline SSID will be used
# in-between these two values the SSID will never be changed to preven it from toggeling every Minute.
# Generate an Offline SSID with the first and last part of the nodename to allow owner to recognise wich node is down
if [ ${#NODENAME} -gt $((30 - ${#OFFLINE_PREFIX})) ] ; then # 32 would be possible as well
HALF=$(( (28 - ${#OFFLINE_PREFIX} ) / 2 )) # calculate the length of the first part of the node identifier in the offline-ssid
SKIP=$(( ${#NODENAME} - $HALF )) # jump to this charakter for the last part of the name
OFFLINE_SSID=$OFFLINE_PREFIX${NODENAME:0:$HALF}...${NODENAME:$SKIP:${#NODENAME}} # use the first and last part of the nodename for nodes with long name
else
OFFLINE_SSID="$OFFLINE_PREFIX$NODENAME" # great! we are able to use the full nodename in the offline ssid
#is there an active gateway?
GATEWAY_TQ=$(batctl gwl | grep "^=>" | awk -F '[()]' '{print $2}' | tr -d " ") # grep the connection quality of the currently used gateway
if [ ! $GATEWAY_TQ ]; # if there is no gateway there will be errors in the following if clauses
GATEWAY_TQ=0 # just an easy way to get a valid value if there is no gateway
if [ $GATEWAY_TQ -gt $UPPER_LIMIT ];
then
echo "Gateway TQ is $GATEWAY_TQ node is online"
for HOSTAPD in $(ls /var/run/hostapd-phy*); do # check status for all physical devices
CURRENT_SSID=`grep "^ssid=$ONLINE_SSID" $HOSTAPD | cut -d"=" -f2`
if [ $CURRENT_SSID == $ONLINE_SSID ]
then
echo "SSID $CURRENT_SSID is correct, noting to do"
HUP_NEEDED=0
fi
CURRENT_SSID=`grep "^ssid=$OFFLINE_SSID" $HOSTAPD | cut -d"=" -f2`
if [ $CURRENT_SSID == $OFFLINE_SSID ]
then
logger -s -t "gluon-offline-ssid" -p 5 "TQ is $GATEWAY_TQ, SSID is $CURRENT_SSID, change to $ONLINE_SSID" # write info to syslog
sed -i "s~^ssid=$CURRENT_SSID~ssid=$ONLINE_SSID~" $HOSTAPD
HUP_NEEDED=1 # HUP here would be to early for dualband devices
else
echo "There is something wrong, did not find SSID $ONLINE_SSID or $OFFLINE_SSID"
if [ $GATEWAY_TQ -lt $LOWER_LIMIT ];
echo "Gateway TQ is $GATEWAY_TQ node is considered offline"
for HOSTAPD in $(ls /var/run/hostapd-phy*); do # check status for all physical devices
CURRENT_SSID="$(grep "^ssid=$OFFLINE_SSID" $HOSTAPD | cut -d"=" -f2)"
if [ $CURRENT_SSID == $OFFLINE_SSID ]
then
echo "SSID $CURRENT_SSID is correct, noting to do"
HUP_NEEDED=0
CURRENT_SSID="$(grep "^ssid=$ONLINE_SSID" $HOSTAPD | cut -d"=" -f2)"
logger -s -t "gluon-offline-ssid" -p 5 "TQ is $GATEWAY_TQ, SSID is $CURRENT_SSID, change to $OFFLINE_SSID"
sed -i "s~^ssid=$ONLINE_SSID~ssid=$OFFLINE_SSID~" $HOSTAPD
HUP_NEEDED=1 # HUP here would be too early for dualband devices
echo "There is something wrong: did neither find SSID '$ONLINE_SSID' nor '$OFFLINE_SSID'"
if [ $GATEWAY_TQ -ge $LOWER_LIMIT -a $GATEWAY_TQ -le $UPPER_LIMIT ]; # this is just get a clean run if we are in-between the grace periode
echo "TQ is $GATEWAY_TQ, do nothing"
if [ $HUP_NEEDED == 1 ]; then
killall -HUP hostapd # send HUP to all hostapd to load the new SSID
HUP_NEEDED=0
echo "HUP!"
fi